50 LIMITED WARRANTY
Problem
• Surface is not level
• Oven is tipping
• Oven shows error
code (F9, F19) but
cooktop burners are
working.
• Flames too big on
converted cooktop
(NP  LP)
• Flame is too small or
too large
Cause
1. Range not leveled
2. Anti-tip device not installed correctly
Level both sides of range
Approximately
0.65"
(16.5 mm)
2
1
The gas pressure regulator valve is closed.
Lever's closed position
The installer missed part of the conversion.
(Check 3 parts: regulator, cooktop nozzles,
broil/bake nozzles.)
regulator
cooktop nozzles
17K burner needs choke.
Set Screw
Choke
Burner
base
1. Variable gas pressure
2. Installer did not check
Center adjustment screw
Anti-tip bracket
Wall plate
Screw must
enter wood or
concrete
Use carpenter's level to
check level.
broil/bake nozzles
Burner
cap
choke
Prevention
• Check with installer first
• Check that the regulator
valve is in the open position.
• If the regulator valve is
closed, rotate the lever to
open the valve.
Lever's closed
Lever's open
position
position
• Check with installer first
• Refer to installation manual
• Check with installer first
• Refer to installation manual
• Check with installer first