Plug in the power, a "Ding tone" will sound. The buttons will light up green for 1 second and then turn
off. At this point the unit is in standby state, the POWER button is lit red while all the others are off.
"Power" Button
In standby state, press the "POWER" button, the unit will
start up and enter the "AUTO" mode by default.
"Ventilator Speed" Button
Press this button to exit the AUTO mode, the "VENTILATOR
SPEED" button light will turn on and the digital screen
shows the current ventilator speed level. Continuously
operate this button and the ventilator speed level can be
adjusted to: 2→3→4→5→1→2 etc. cycle switching. The
PM2.5 index display reappears after 3 seconds of operation.
"Timer" Button
When powered on or in standby state, press the "TIMER"
button to set the timer 1H→2H→4H→6H→8H→10H→12H
to turn the unit off or on respectively.
"Child Lock" Button
Long press the "Child Lock" button for 3 seconds to turn
on the child lock function. When the child lock function is
turned on, the button light is on and all other buttons will
not respond (are locked).
Long press the "Child Lock" button for 3 seconds again
to exit the child lock function, the button light will turn
off. (Under the child lock function, the device cannot
be turned off. First Press the "Child Lock" button for 3
seconds to unlock. Then the device can be switched off
as normal.)
"AUTO Mode" Button
In the power-on state, the air purifier runs in AUTO mode
by default. After pressing the "AUTO" button, the unit
will exit the AUTO mode and enter the manual mode (the
"Ventilator Speed" button will be lit).
Press again to enter the AUTO mode. In AUTO mode, the
wind speed will be automatically adjusted according to
the air quality index.
In the dark after 30 seconds working in the AUTO mode,
the unit will enter "AUTO SLEEP" mode and the indicator
light will change from bright to dim.
When "AUTO SLEEP" is on, the "SLEEP MODE" and "AUTO
MODE" button light are on at the same time (used to
distinguish between "Auto sleep" mode or "Manual sleep"
mode) and other lights are off.
Note: By default, the "AUTO SLEEP" function is turned off.
To turn the light sensor on, long press the timer button
and sleep button together for 3 – 5 seconds until you
hear a "beep tone". Do the same to turn the "AUTO SLEEP"
function off.
Air quality
The degree of air pollution is visible in the form of a
concentration of hazardous particles PM2.5 µg / m³.
Excellent
Green
Good
Blue
Moderate
Yellow
Very Bad
Red
0~50 µg/m
3
51~100 µg/m
3
101~150 µg/m
3
151~500 µg/m
3
User Manual ecoQ CleanAir 800
|
55