Mounting by through bolt joint
Attach connecting piece with G ½ internal thread to the tube. Recom-
mended length of the connecting piece: 10 to 30 mm
Pull protective sleeve from sensor head 9.
Unscrew the nut of the through bolt joint and slide the joint carefully
over the sensor head and the sensor tube.
Introduce through bolt joint into the tube connection and tighten it. Intro-
duce sensor into the joint until the desired immersion depth is reached.
Next tighten the spigot nut of the through bolt joint.
If a gas-tight connection is required, the mounting thread must be
wrapped with a commercially available sealing tape, for example made
of PTFE, prior to mounting.
Note:
The through bolt joint 301082 is only designed for use in pressure-
free systems.
MET = 58,5
50
SL
D /2
A
L - 8,5
L
Seite 25
AL= L - 8,5 - D /2 + 47
A
L
16
DGV
47