Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Wet vacuum cleaning
Remove the membrane filter.
– To suck wet dirt, always remove the
membrane filter.
– It is recommended to use a special filter
bag (optional) (wet) (see Filter sys-
tems).
Warning
The flat pleated filter must must always be
in place while vacuuming.
– If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
– If the maximum liquid level is reached
the appliance will turn off automatically.
– In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
– When suckung up oil or grease-contain-
ing liquid, we recommend installing the
upgrade kit for non-conducting media,
order no. 2.641-560.0 (optional).
– After having completed the wet vacuum
operation clean the flat pleated filter,
the electrodes and the container and let
dry.
Clip connection
Many suction hoses (optional) are
equipped with a clip system. All C-35/C-
DN-35 accessories can be connected.

Operation

Warning
At the latest after 50 oven cleanings, the flat
folded filter must be replaced.
Warning
In order to ensure a safe operation of the
vacuum cleaner, you must never suck up
hot air for more than 5 minutes at a time.
Turning on the Appliance
Plug in the main plug.
Turn on the appliance.
Automatic filter cleaning
The appliance has an innovative filter
cleaning system that is particularly effective
with fine dust. The flat pleated filter is auto-
matically cleaned every 15 seconds
through an air jet (pulsating sound).
9
English

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nt 55/1 eco bs