Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Mounting
Tower Mounting
To mount the UPS in an upright (tower) position, Tripp Lite's 2-9USTAND accessory
is required (sold separately).
Once mounted, rotate the power module's Control Panel for easier viewing while the
UPS is upright. Insert a small screwdriver, or other tool, in the slots on either side of
the Control Panel. Pop the panel out, rotate it, and pop the panel back into place.

Features

Before installing and operating your UPS, familiarize yourself with the location and function of the features of each component.
Power Module Front Panel Controls
LCD DISPLAY: This backlit (16 × 2 character) dot matrix display indicates a wide
1
range of UPS operating conditions and diagnostic data. It also displays UPS
settings and options when the UPS is in setup mode.
ON/MUTE BUTTON: Press this button and hold it until you hear a beep to turn
2
the UPS system's inverter ON. If the UPS's battery alarm is sounding, press this
button to silence it.
SCROLL DOWN/EXIT SETUP BUTTON: This button allows you to browse through
3
different options and power readings on the LCD display. Momentarily pressing it
causes the LCD screen to display a different power reading (see "Operation"
section). Pressing it and the SCROLL UP button together puts the UPS in setup
mode, where this button is used to scroll through setup options and to exit setup
mode.
SCROLL UP/SELECT BUTTON: This button allows you to browse through different
4
options and power readings on the LCD display. Momentarily pressing it causes
the LCD screen to display a different power reading (see "Operation" Section).
Pressing it and the SCROLL DOWN button together puts the UPS in setup
mode, where this button is used to select setup options.
OFF BUTTON: Press this button until you hear a beep to turn the UPS system's inverter OFF.
5
O/P (OUTPUT) LED: This green light will illuminate to indicate your UPS is supplying AC power to connected equipment.
6
DC/AC (INVERTER) LED: This green light will illuminate to indicate the UPS's DC/AC inverter is activated.
7
BYPASS LED: This yellow light will flash when the UPS is providing filtered mains power without engaging the converter or
8
inverter. If this LED is flashing, connected equipment will not receive battery power in the event of a blackout. If Economy Mode
is enabled, this LED will be on solid and the connected equipment will receive power in the event of a blackout.
AC/DC (Converter) LED: This green light will illuminate to indicate the UPS's AC/DC converter is charging the connected
9
battery pack(s).
BATTERY LED: This green light will illuminate when the UPS is discharging the battery to provide connected equipment with AC
10
power. An alarm will sound which can be silenced by pressing the ON/MUTE button. This LED will remain lit after the alarm is
silenced.
I/P (INPUT) LED: This green light will illuminate to indicate an AC input supply is present.
11
201207113 933070.indb 4
4
11
10
9
8
7
6
1
2
3
4
5
9/17/2012 1:19:46 PM

Publicité

loading

Ce manuel est également adapté pour:

Smartonline su6000rt4uhvgSmartonline su5000rt4utf