pump does not operate; for flow rates exceeding the peak flow rate the dosage of AcquaSIL 20/40
reduced. As a consequence, the overdosage of AcquaSIL 20/40
®
20/40
in the tank is not signaled by any automatic device, but it is visible from the emptying and crushing of
the tank itself. Check the tank filling degree periodically. When the filling degree drops below the minimum it
is necessary to refill the tank. A prolonged dry running may cause a temporary blockage of the pump (see A3
troubleshooting); moreover, the missed dosage of AcquaSIL 20/40
against scale and corrosion.
A1.6 What's AcquaSIL 20/40
®
AcquaSIL 20/40
is a ready-to-use (do not dilute) aqueous solution of food grade sodium polyphosphates
used to prevent incrustation and corrosion.
Anti-scaling effect: AcquaSIL 20/40
formation of scale deposits.
Anti-corrosive effect: AcquaSIL 20/40
heat exchange phenomena, but it is very efficient in protecting the metal surfaces from corrosive
phenomena.
®
Keep AcquaSIL 20/40
ranging from 5 °C and 35 °C. Keep out of the reach of children.
For any further information about AcquaSIL 20/40
Technical data sheet. Ask for these documents to Acqua Brevetti 95 s.r.l. or visit the website
www.acquabrevetti95.it.
A1.7 MiniDOS performances and technical datasheet
Connections
Minimum flow rate
Peak flow rate
Min–max water hardness
Max. instantaneous heating temperature
Max temperature for stored hot water
Tank volume – refill autonomy
Min-max water pressure
Min-max water temperature inside MiniDOS
A1.8 Specification for water to be treated
MiniDOS has been designed and created for the treatment of drinking water.
If the water to be treated is not potable please contact Acqua Brevetti 95 s.r.l. (tel. +39.(0)49.8973432, e-
mail: info@acquabrevetti95.it).
The dosing of AcquaSIL 20/40
The P
O
concentration in water treated by MiniDOS is lower than 5 mg/l. This value refers to water having,
2
5
before being treated by MiniDOS, a concentration of P
MiniDOS cannot be used to treat water containing chemicals of any kind (e.g. acids, bases, solvents,
detergents, antifreezes, glycols, etc.).
A2 INSTRUCTIONS FOR PERIODIC MAINTENANCE
A2.1 Periodic maintenance
Perform periodically the following checks:
For checking AcquaSIL 20/40
MAN 127
MINIDOS - ENGLISH
®
®
interfere with the carbonate crystallization phenomena hindering the
®
form a protective layer on metal surfaces which is not able to hind the
in a clean place away from direct sun and heat sources with room temperature
®
in water increases its content of phosphorus.
®
consumption
®
is not possible. The lack of AcquaSIL
®
does not guarantee the protection
®
please read the Material Safety Data Sheet and the
Units
PM008
DN
½" M
lt/min
3
m
/h
lt/min
27
3
m
/h
1,6
°f
°C
3
3
cm
- m
bar
°C
O
< 0.05 mg/l.
2
5
®
is
PM009
½" F
1,5
0,09
17
1,0
5 - 35
80
60
230 - 10
1.5 - 6
5 - 30
PAG.E-4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pm008Pm009

Table des Matières