6 Assembling and installing
Only specialised personnel should be
allowed to assemble and install the device.
6.3 Installation
Always make the electrical connections
with the power supply disconnected and
the circuit-breaker open.
The receiver includes a safety device that
blocks pump operation at temperatures
lower than -10°C (10°F).
Configure protocol, baud rate and receiver address
via the DS1 dip-switches (Tab. 1, page 3).
Fig. 1
7 Configuration
DIP-SWITCH CONFIGURATION (DS1)
Description
Address
Not available
1
2
3
...
31
Protocol and
VIDEOTEC MACRO
baud rate
9600
VIDEOTEC MACRO
38400
PELCO D 2400
PELCO D 9600
Termination of RS-
Line terminated
485 line
Line not terminated
Tab. 1
Open the box of the WASPT device.
Connect telemetry lines A and B to connector J9
(WASPT board) as described in the relative manual.
We recommend using a twisted cable with minimum
section of 0.22mm²/0.8in² (AWG24).
If the receiver is connected to one of the head
communication channels RS-485, the line must be
terminated (SW8 column, Tab. 1, page 3).
Insert the DTWRX board in the specific J8 housing
and close the box of the WASPT device.
Fig. 2
Supply power to the device, checking that the
controls function correctly from the start.
SW 1
SW 2
SW 3
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
...
...
...
ON
ON
ON
SW 4
SW 5
SW 6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
ON
ON
OFF
ON
OFF
ON
SW 7
SW 8
OFF
OFF
ON
ON
ON
OFF