Seven different standard installation numbers are available. Each number uses one rinsing valve,
one flushing valve and one air valve. The selected installation number decides the function of the
remaining valves. Please find below list of installation numbers
Warning:
When delivered the installation is pre-programmed by the supplier.
Please be aware, that all existing programs will be erased if the pre-programmed installation
number is changed.
4 Information
In case of errors or an emergency stop, an error notification will appear in the display. The errors
are of various priorities, depending on how the error will affect the cleaning process.
Errors on internal valves
An error might occur on the rinsing valve, air valve, flushing valve or on the various product valves.
These types of errors are high priority errors, as the washing procedure will be interrupted.
Errors on area valves
An error might occur on the various area valves. The number of valves might vary from 1 to 99
valves.
These types of errors are low priority errors as the washing procedure will be able to continue as
planned. However, the cleaning step affected by the error will be replaced by a pause. The time of
this pause will be equal to the pre-programmed time of the cleaning step.
This means that the total cleaning time will remain the same and the detergents will be effective as
planned.
Emergency stop
If the emergency stop is activated an error notification will be displayed. In order to accept the error
notification and reactivate the unit using the green button, the emergency stop must be deactivated.
Accept error using the
navigation button.
Inst. no. Valve 1 (Y4) Valve 2 (Y5) Valve 3 (Y6)
1
Foam
2
Foam
3
Foam
4
Foam
5
Foam
6
Foam
7
Foam
Spray
Foam
Foam
Foam
Foam
Spray
Spray
Foam
Spray
Spray
32