Ribimex Ribiland PRMCA5AUTOV Manuel D'instructions page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Trouble
Main reasons
Difficult start 1. Power voltage too low;
2. Impeller clogged
3. Big loss of cable voltage
4. Stator winding burnt
Less water
1. Head too high
outlet
2. Strainer and inlet hole clogged
3 Impeller worn badly
4. Submersion too shallow and air sucked in.
5. Discharge hose disconnected, leaking or
worn out
Sudden stop
1. Switch disconnected or fuse burnt
2. Impeller clogged
3. Stator winding burnt
Stator
1- Run too long
winding
2. Winding turn-to-turn short circuit or short
burnt
circuit between phases due to mechanical seal
leakage
3. Impeller clogged
4. Pump started too frequently
5. Pump overloaded
6.3- Storage
Product must be stored in a dry location. Always lock up product and keep out of reach of children.
6.4- Disposal
- Do not dispose the product with household garbage. Do not throw into the environment.
- Dispose of the product in a collection centre for waste of electrical and electronic equipment, or a waste
drop-off centre; or seek advice from your local municipality.
- Disposal of the product, accessories and packaging should be carried out according to local regulations
governing environment protection.
Our warranty conditions are available from our STAV department [*] and on our website.
Should you have any repair requests under the warranty, please contact your retailer or our STAV [*] who
will inform you on the procedure.
Should you have any parts and/or accessories request, you can contact our STAV [*] to ask for the product
exploded view by indicating our reference and the serial number or batch number appearing on the nameplate.
[*] STAV = Technical and After-Sales Service department
STAV contact details:
Tél : 08 92 35 05 77 (0,34€/min ; only in France) ; email :
Internet Website:
www.ribimex.com
Ribimex, 56 Route de Paris, F-77340 Pontault-Combault.
Solution
1. Adjust voltage to 0.9 to 1.1 times the
rated range.
2. Adjust clogged part.
3. Select the proper cable
4. see below
1. Use within the rated head range
2. Remove water weed or foreign matter
3. Replace impeller
4. Adjust the submersion depth to no less
than 0.5m
5. Check hose connection, fix it or replace if
required.
1. Check whether the head in use or power
voltage comply with requirements and
adjust accordingly.
2. Remove foreign matter
3. See below
Seek assistance from vendor or authorised
service centre
sav@ribimex.fr