Mounting and securing
6.8
Functional test - Closing sequence control
X
Set the closing time for the secondary and the moving leaf (1.).
Recommended:
à Closing time for moving leaf 5 seconds (from 90°).
à Closing time for fixed leaf 5 seconds (from 90°).
X
Open fixed leaf by 90° and hold fixed (2.).
X
Open the moving leaf by 90° (3.).
X
Let the moving leaf close (4.).
The door should stop at an opening angle of >35°.
X
Now close the fixed leaf (5.). The lock is released and the moving leaf closes.
6.9
24 V Mains connection
X
Place the mains cable provided on site on the terminal (1.).
X
Shorten excess cable.
X
Connect cable to terminal (2.). Electrical hold-open device is powered.
6. 1 0 Adjusting electrical hold-open device
Moving leaf is shown.
X
Open door leaf to desired hold-open angle and fix it there (1.).
X
Remove cable protection foils from guide (2.).
X
Loosen clamping screws of electrical hold-open device (3.).