Output Connection - Elkron MR16 Guide D'utilisation Rapide

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RADIO MODULE A RELAIS MR16
MR16 system allows to add wireless devices to an anti-intrusion system, although not prearranged to
manage radio devices.
SYSTEM MAXIMUM DIMENSIONS
Bidirectional radio module MR16 can manage up to:
16 radio input devices (micro contacts DC500 and volumetric detectors IR500) on choice.
2 sirens either indoor (IS500) or outdoor (HP500).
8 remote controls RC500.
8 output connections to wired alarm control panel for detectors warnings.
4 alarm connections to wired alarm control panel.
2 output connections per command and status repetition to wired alarm control panel.
2 input connections from wired alarm control panel.

OUTPUT CONNECTION

Connect radio module relay outputs to wired alarm control panel inputs according to what indicated in the
table. Do not exceed voltages and currents accepted for solid state relays. The status of the relay at rest
(normally open or normally closed) is defined by DIP switches.
Warning: the black dot identifies the polarised terminal block of the relay output.
The polarisation of each output can be changed by modifying the position of corresponding jumper
Outputs OUT1÷OUT8
at rest
in alarm condition
Outputs OUT1÷OUT8
at rest
in alarm condition
Output
free from
potential
DIP switch A5 = OFF
Free from potential
Closed contact
Open contact
Free from potential
Open contact
Closed contact
GB
Output
positive
polarisation
Positive polarisation
12 V
-
DIP switch A5 = ON
Positive polarisation
-
12 V
8
Output
negative
polarisation
Negative polarisation
0 V
-
Negative polarisation
-
0 V
.

Publicité

Table des Matières
loading

Table des Matières