Relay operation mode
Bistable
(DIP switch A4 = OFF)
Monostable
(DIP switch A4 = ON)
Output
Jumper
OUT1 ÷ OUT8
J1 ÷J8
SAB
J9
RF SAB
J10
BATT
J11
ON/OFF
J12
SYS ST
J13
Operating modes of output relays OUT1 ÷ OUT8
Subordinated to
radio module status
Enabled
(DIP switch B1 = OFF)
Disabled
(DIP switch B1 = ON)
Enabled
(DIP switch B1 = OFF)
Disabled
(DIP switch B1 = ON)
Outputs directly associated to detection devices (micro contacts and IR
detectors). Each relay can be associated to two detectors (detectors 1 and 9 at
output 1, detectors 2 and 10 at output 2, etc.).
When an input device warns about an alarm, the relay switches over
depending on radio module MR16 configuration. Table Operating modes of
output relays OUT1 ÷ OUT8 shows possible output operating modes.
Outputs used are to be connected to wired control panel detector inputs.
If PHYSICAL SABOTAGE function is enabled by programming, the relay
switches over if at least one device warns about physical sabotage (tamper
open). The output can be connected in series to wired alarm control panel
tamper input.
If JAMMING DETECTION and/or SUPERVISION ENABLING functions were
enabled by programming, the relay switches over whenever radio sabotage
(jamming and/or missing supervision) is detected. The output can be
connected to wired alarm control panel sabotage input (or in series to tamper
input, where sabotage input is missing).
The relay is armed where one or more devices warn out that battery is low.
The output can be connected to wired alarm control panel faulty input.
The relay is managed with remote control RC500.
When, on remote control, you press radio module MR16 arm control, the
relay switches:
• first to OFF and remains OFF for 500 ms and then to ON and remains ON
for 400 ms, if it is configured as NC,
• first to ON and remains ON for 500 ms and then to OFF and remains OFF
for 400 ms, if it is configured as NO.
When, on remote control, you press radio module MR16 disarm control, the
relay switches:
• first to OFF and remains OFF for 1000 ms and then to ON and remains
ON for 400 ms, if it is configured as NC,
• first to ON and remains ON for 1000 ms and then to OFF and remains
OFF for 400 ms, if it is configured as NO.
The output can be used to arm and disarm wired alarm control panel,
connecting the output to the "mechanical key" input of wired control panel, if
it is provided with it.
Relay output follows radio module MR16 armed or disarmed status.
This output can be used to display radio module MR16 status, e.g. by
connecting an external LED.
Operating mode
When radio module MR16 is armed, the output
follows associated detection device.
Detection device 1 open
Detection device 1 closed -> relay 1 disarmed
The output always follows associated detection
device.
Detection device 1 open
Detection device 1 closed -> relay 1 disarmed
When radio module MR16 is armed, the output is
armed and remains armed for about 1 second at
every opening operation on associated detection
device
The output is armed and remains armed for about 1
second at every opening operation on associated
detection device
Description
9
-> relay 1 armed
-> relay 1 armed