CONFIGURATION

Radio module MR16 operation is configured via DIP switch.
Command
DIP
Function
switches
A1 - A2
The switches arm wireless devices
acquisition and removal steps
A3
Arm test
A4
Output relay operation mode for inputs
1÷16
A5
Output relay typology for inputs 1÷16
A6
Output relay typology SYS ST
A7
Output relay typology ON/OFF
A8
Output relay typology SAB / RF SAB /
BAT
B1
Outputs 1÷8 subordinated to radio
module status
B2
Enable jamming detection (radio
sabotage)
B3
Enable supervision
(radio sabotage)
B4
Enable radio module MR16 buzzer
B5
Enable PHYSICAL SABOTAGE alarm
B6
Input S polarity
B7
Inhibit sirens tamper for 1 hour
B8
Silence sirens audio warnings
Key
Settings
A1
A2
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
= normal operation
ON
= test procedure armed
OFF
= bistable
ON
= monostable
OFF
= normally closed (NC)
ON
= normally open (NA)
OFF
= normally closed (NC)
ON
= normally open (NA)
OFF
= normally closed (NC)
ON
= normally open (NA)
OFF
= normally closed (NC)
ON
= normally open (NA)
OFF
= outputs subordinated
ON
= outputs not subordinated
OFF
= jamming control disarmed
ON
= jamming control armed
OFF
= supervision disarmed
ON
= supervision armed
OFF
= buzzer enabled
ON
= buzzer disabled
OFF
= physical sabotage alarm enabled
ON
= physical sabotage alarm disabled
OFF
= negative polarity
ON
= positive polarity
OFF
= siren rings at tamper opening
ON
= siren does not ring if tamper is opened
within one hour from DIP switch having
switched over
OFF
= sirens do not acoustically warn about
the change of status of radio module MR16
ON
= sirens acoustically warn about the
change of status of radio module MR16
11
normal operation
acquire devices
remove a device
remove all devices