CONNECTING INPUTS

Radio module MR16 is provided with inputs through which it can learn wired system status and receive
commands from the system. Input polarity (reference to either positive or negative polarisation) is defined by
DIP switch B6.
Below table shows connections to be made:
Input
Description
This input must be connected to an output of wired control panel which follows control panel
status.
The value of voltage depends on input polarity chosen:
• positive polarity (DIP switch B6 = ON): by applying 12 V voltage, the module, if armed, is
S
disarmed; taking off the voltage, the module, if disarmed, is armed.
• negative polarity (DIP switch B6 = OFF): by applying 0 V voltage, the module, if armed, is
disarmed; taking off the voltage, the module, if disarmed, is armed.
This input is used to drive wireless sirens, by acknowledging a voltage at its terminal block.
BL
This input must be connected to an output of wired control panel which is armed when the
sirens are armed. By applying 12 V voltage to the terminal block, radio sirens are silenced;
taking off the voltage, the sirens ring.
Tamper MR16 connection
Terminal blocks TMP are a support to radio module MR16 tamper connection and must be taken back to
wired anti-intrusion control panel.
VISUAL AND ACOUSTIC WARNING
Radio module MR16 front side is provided with LEDs displaying the status of system and its radio devices.
LED
Colour
1÷16
Red
Red
Red
Yellow
A
Green
(IN)
B
Green
(OUT)
C
Green
(RC)
Meaning
Status of corresponding
radio detector
Physical sabotage
Radio sabotage
Battery status
Device type identification
Device type identification
Device type identification
On
Input open or movement
detected
Tampers of one or more devices
stressed (device open).
LED
blinking
until
examines alarm details
• One or more devices did not
reply to supervision
• A radio transmission tries to
black out communications
LED blinks until user examines
alarm details
One or more devices are in
battery low condition
Indicating that the device is a
detector (micro contact or IR
detector)
Indicating that involved device is
a siren
Indicating that involved device is
remote control
10
Off
Input closed or no
movement
No sabotage to devices
user
No sabotage to devices
Battery charger suitable