AXIS P55 Network Camera Series
Function
Pin
1
0 V DC (-)
2
DC output
3–6
Configurable
(Input or
Output)
For an example diagram, see Connection Diagrams on page 15.
I/O connector
1
2 3 4 5 6
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power
out.
Digital input – Connect to pin 1 to
activate, or leave floating (unconnected)
to deactivate.
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive
load, e.g. a relay, a diode must be
connected in parallel with the load, for
protection against voltage transients.
DC power input
14
AC power input
Specifications
3.3 V DC
Max load =
250 mA
0 to max 40 V DC
0 to max 40 V DC,
open drain,
100 mA