CONTROLS
A
A: Power button
- Power Button will turn power on and off for the entire hood (fan and lights).
- Hood will remember the last speed and light level it was last turned off at.(Example:
hood is turned off at when it was last on high speed and high lights; hood will turn back
on at high speed and high lights when Power Button is pressed).
B: Fan Speed button
- From off, press once for low speed (1), twice for medium (2), and three times for high (3).
- Fan should cycle through speeds low (1), medium (2), and high (3) continuously.
C: Light button
- Lights are three level (high, medium, low).
- From off, touch once for high.
- From off, touch twice for medium.
- From off, touch three times for low.
- From off, touch four times to cycle back to off.
- Light level will cycle from high, medium, low, off.
D: Delay off button
- Press this button to enable the five minute delay-off function. After five minutes the fan
and lights will power off.
- If the fan is already on (example high speed) the fan will change to low speed when the
Delay Off Button is pressed and turn off after five minutes.
- When the Delay Off Function is on, the user can still change the fan speed by pressing
the Fan Speed Button without interrupting the five minute Delay Off Timer.
- Delay Off Function can be turned off by pressing Delay Off Function button or Power
Button.
G: Light indicator
- Light indicator will turn on when lights are turned on at any light level.
H: Filter clean and charcoal filter replace indicator
- Mesh filter clean (always enabled):
- Filter Clean Indicator will illuminate after 30 hours of fan usage indicating it is time to
clean the mesh filter. Indicator light will remain illuminated, it will not blink.
- This function must be reset by the user. With hood off, hold the Fan Speed Button for
five seconds, after five seconds the Filter Clean Indicator will turn off and the 30 hour
timer will reset.
- Charcoal filter replace (disabled by default, must be enabled by user if recirculating hood):
- To enable Charcoal Filter Replacement Function:
- With hood off, hold Fan Speed and Delay Off buttons simultaneously for 5 seconds.
Filter Clean Indicator will quickly flash 3 times indicating the Charcoal Filter Replacement
Function is enabled. Filter Clean Indicator will continuously blink after 120 hours of unit
E
F
H
B