Restoration; Shut-Down; Replacement; Maintenance - GOK Caramatic DriveOne Instructions De Montage Et D'utilisation

Masquer les pouces Voir aussi pour Caramatic DriveOne:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RESTORATION

If the actions described in TROUBLESHOOTING do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.

SHUT-DOWN

Close the gas supply and then the shut-off fittings of the connected loads. When the LPG
system is not in use, all valves must remain closed.
Close all free connections in the feed lines of the LPG system tightly with a suitable cap to
prevent gas from flowing out.

REPLACEMENT

If there is any sign of wear or if the product or parts thereof are damaged,
it must be replaced. When the product has been replaced, observe the steps
ASSEMBLY, LEAK TESTING and START-UP.
To ensure that the installation works faultlessly under normal operating conditions, it is
recommended to replace system parts subject to wear or ageing, e.g. pressure regulators,
hose assemblies, shut-off devices, as required:
• Recommendation: replacement times 5 years.
The gasket in the inlet connector (if provided) must be changed every time the cylinder has
been replaced or disassembled. It must also be replaced if it is damaged or the connection is
no longer tight.

MAINTENANCE

Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.

TECHNICAL DATA

Maximum admissible pressure
Inlet pressure p
Nominal regulated pressure
Nominal flow rate M
Maximum permitted pressure drop in the
downstream installation
S2SR (OPC)
Housing material
Ambient temperature
For additional technical data or special settings, see type label of the product!

TECHNICAL CHANGES

All the information contained in this assembly and operating manual is the result of product
testing and corresponds to the level of knowledge at the time of testing and the relevant
legislation and standards at the time of issue. We reserve the right to make technical changes
without prior notice. Errors and omissions excepted. All figures are for illustration purposes
only and may differ from actual designs.
g
Caramatic DriveOne
PS 16bar
0.3 to 16bar
p
alternatively 30 or 50mbar
d
1,5kg/h
ΔP5
100 or 150mbar
die-cast zinc ZP0410
-30°C to +60°C

Publicité

Table des Matières
loading