Télécharger Imprimer la page

Bosch DUH36252UC Mode D'emploi page 5

Masquer les pouces Voir aussi pour DUH36252UC:

Publicité

Les langues disponibles

Les langues disponibles

Parts Included with your Hood
Hood Canopy Assembly with Round Metal
Transition installed.
Rectangular Metal Transition with Back draft
dampers.
Care & Use /Installation Instructions
2 Filters
Fitting Screws.
For the most efficient air flow exhaust, use a
straight run or as few elbows as possible.
CAUTION: Vent unit to outside of
building, only.
One person is necessary for installation.
On avarage 2 hours are necessary to complete
installation (without considering cut to be done
on wall and or on cabinet, installation of ducts ,
conduit and electrical connections to the mains).
16 installation steps are required.
The hood is fitted with Screws and Drywall
Anchors suitable for most surfaces, consult a
Qualified Installer, check if they perfectly fit with
your cabinet/wall.
Do not use flex ducting.
COLD WEATHER installations should have an
additional backdraft damper installed to
minimize backward cold air flow and a
nonmetallic thermal break to minimize
INSTALLING THE HOOD
Parts Not Included with your
Hood
Duct Tape
1/2" Conduit
Wire Nuts
Round or Rectangular Duct.
Charcoal filters
Round back draft damper
Wiring clamp
Models DUH30252UC and DUH36252UCOnly:
CAUTION! Lamps are not supplied, use
ONLY 120 Volt, 50 Watt (maximum) 50°
halogen light made or a GU10 base.
Tools required
Flat blade and Phillips screwdrivers
Pencil
Metal snips (in some applications)
Electric drill
Saw (saber or keyhole)
Duct tape
Pliers
Level
Caulking
Tape measure
1/4.pivoting hex socket
Flashlight
Wire stripper
1/4. Nutdriver
Small hammer
conduction of outside temperatures as part of
the ductwork. The damper should be on the
cold air side of the thermal break.
The break should be as close as possible to
where the ducting enters the heated portion of
the house.
Remote blowers require a five wire installation.
Make up air: Local building codes may require
the use of Make-Up Air Systems when using
Ducted Ventilation Systems greater than
specified CFM of air movement.
The specified CFM varies from locale to locale.
Consult your HVAC professional for specific
requirements in your area.
Typical installation
Min installation height from the countertop to the
bottom of the hood is 24" to 30".These hoods
are not recommended to be used over indoor
grills.
5

Publicité

loading

Ce manuel est également adapté pour:

Duh30152ucDuh30252ucDuh36152uc