H-Tronic AL 800 Mode D'emploi page 14

Masquer les pouces Voir aussi pour AL 800:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

AutomAtic chArGer
AL 800
the i-u-chArGiNG coNcept
current of 800 mA (0,8A) until the end of charge voltage is reached for the
respective battery. The charger recognises this and switches to constant
current in order to adjust the charging current down (Maintenance charger).
The battery charger is therefore maintained at an ideal level. As a result, the
battery can be plugged into the charger for a longer period of time. This is
the reason why this device is suitable for "over wintering". The plug charger is
protected against overcharge and short-term short-circuit (<1min.). A protective
circuit avoids charging in case of incorrect poling that could destroy the
battery as well as the charger. Incorrect poling will be indicated by a red
light.
FeAtureS
– For 2 V, 6 V and 12 V lead batteries (Lead-gel,
leadfleece or lead-acid)
– Electronic protection against short-circuits (<
1 min.) and incorrect polarity
– Automatic battery maintenance
mode (Automatic refreshing of
the battery after charging)
– Constant charging end voltage
– I/U charging characteristic
– No charging takes place when
the battery is connected to the
wrong polarity
– 3 LED status displays: Mains,
charging, wrong polarity
14 | Features
charges the lead-battery with constant
techNicAl dAtA
– Operating voltage:
230 VAC/50 Hz
– Charging end voltage: 2.3 V,
6,9 V, 13,8 V max.
– Max. charging current 800 mA
for lead batteries 1.2 – 63 Ah
– Protection class: IP20
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2 24 32 18

Table des Matières