Troubleshooting

SYMPTOM
CAUSE
Motor piston
Dosatron does not
start or stops
The units has not
been bleeded
The bypass is
closed or half
open
Maximum flow
exceeded
Damage inside
the unit
Injection
Water flowing back
Contaminated,
worn, or missing
into concentrate
check valve parts
container
No suction of
The piston motor
has stopped
concentrate
Check the suction
height (4< m)
Air leak (inlet) in
the suction tube
Blocked suction
tube or clogged
strainer
©
DOSATRON INTERNATIONAL / 51
SOLUTION
Check that your installation
allows your unit to operate
correctly
Check that the water
supply is open and that the
solenoid valves are supplied
with power
Refer § Putting into Order
Open the bypass. Refer §
Incorporated bypass
Reduce flow restart unit
Clean or replace them
See Motor piston section
Reduce the suction
height if necessary
Check the tightness between
nut and suction hose
Clean these parts.
Attention: Do not put the
strainer on the ground of the
tank (min. distance 10 cm)