Assembling The Dosatron - dosatron D 20 S Manuel D'utilisation

20 m3/h - 100 gpm
Masquer les pouces Voir aussi pour D 20 S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
PRECAUTIONS (cont...)
1 - GENERAL REMARKS (cont...)
- Before applying any aggressive
chemicals, please consult your
distributor to confirm compatibility
with the dosing pump.
- All assembly should be done
without tools, hand tighten only.
2 - WATER WITH HIGH PARTICLE
CONTENT
- A (ex.: 50 mesh - 300 microns
depending on your water quality)
water filter must be installed
upstream
from
the
Dosatron
(see accessories), if a filter is not
installed abrasive substances will
cause the Dosatron to deteriorate
prematurely.
3 - WATER-HAMMER / EXCESSIVE
FLOW
- For installations subject to water
hammer a protection device such
as a check valve or union ball check
must be fitted (pressure/flow
control system).
- For automatic installations, slow
opening and closing solenoid valves
are preferable.
- In an installation where a
Dosatron serves several sectors,
the closing of one sector and the
opening of another sector must be
done at the same time (simultaneous
operation of the solenoid valves).
©
DOSATRON INTERNATIONAL / 36
4 - INSTALLATION LOCATION
- The location of the Dosatron and
concentrate container should be
accessible, but should never present
a risk of pollution or contamination.
- It is recommended to label all
water lines with a warning about
the injected solution i.e. Not For
Human Consumption.
5 - MAINTENANCE
- Rinse the injection areas after
using the Dosatron. To do this, insert
suction tube into a container of
clean water and inject about 1 liter
[0.264 US Gallons].
- Routine maintenance once a year
will add to the life of your Dosatron.
Replace the dosing seals as well as
the suction tube annually to ensure
proper injection.
6 - SERVICE
- This Dosatron was tested prior to
packaging.
- Complete maintenance and seal
kits are available.
- Call your DOSATRON® distributor
for service or parts.

ASSEMBLING THE DOSATRON

ASSEMBLY SHOULD BE CARRIED OUT WITHOUT THE USE OF TOOLS
Model D 20 S
The Dosatron is delivered with:
- a support legs,
- a suction tube with strainer,
- a vacuum breaker + connections.
- Insert the legs in the hoses (Fig. 1).
- Fix them with the 4 pins.
©
DOSATRON INTERNATIONAL / 37
Fig. 1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

D 20 sp

Table des Matières