Télécharger Imprimer la page

Zibro SRE346E Manuel D'utilisation page 42

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
shuts off automatically. When this occurs, e -1 1 is displayed and the
is blinking and VENT indicator (
room (e.g. by opening a door or window a little more), the heater can be ignited
by pushing
M again.
L
MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
work. Also disconnect the plug from the mains. Your Zibro needs hardly any
L
maintenance. It is, however, important that you clean the air filter 8 and the
vent filter 9 with a vacuum cleaner and the grid 2 with a damp cloth, both on a
weekly basis. Remove the air filter cap occasionally (Fig. L) and clean it with soapy
water. Prior to reinstallation, make sure that the air filter cap has fully dried.
Regularly inspect the fuel filter as well:
1
Remove the removable tank 7 from the heater and remove the fuel filter
Fuel filter
(Fig. M). Some drops may leak from the filter; keep a cloth at hand.
M
2
Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(Never clean it with water!)
3
Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains in time with a damp cloth,
because otherwise these may cause stains that are hard to remove.
Do not remove any heater components yourself. Always contact your Zibro
dealer for repairs. When the power cord is damaged, it may only be replaced
by an authorised fitter. Use a new cord of the type H05 VV-F.
M
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place,
if possible in its original packaging. Unused fuel cannot be used in the next
heating season. We therefore recommend that you burn up all fuel. If there is
still some fuel left, do not throw it away, but dispose of it in accordance with the
local regulations for the disposal of domestic chemical waste. Always start the
new heating season with fresh fuel. When you start re-using the heater follow the
instructions again (starting from section A and as specified).
N
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
1
Let the heater cool down.
2
Remove the removable tank G from the heater and remove the fuel filter
(refer to Section L, Fig. M). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater.
4
82
p074_087_uk_SRE346E.indd 82-83
indicator
) is lit. After improving the ventilation of the
N
3
Place the transportation cap into the position of the fuel filter (Fig. N).
Press it tight. The transportation cap will, as much as possible, prevent oil
leakage from the heater during transport.
4
Always move the heater in an upright position.
5
Make the fixed tank empty with a fuel pump before transportation or in case
of wrong or dirty fuel. First remove the fuel filter and then insert the fuel
transportation
pump into the empty fixed tank. Follow the same procedure if the fuel tank
cap
contains water.
O
SPECIFICATIONS
Ignition
Fuel
Capacity (kW) max.
Capacity (kW) min.
Suitable space (m
)
3
**
Fuel consumption (l/hr)
Fuel consumption (g/hr)
Burning time per tank (hr)
Capacity removable tank (litres) 7.6
Weight (kg)
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
* At maximum setting
P
WARRANTY PROVISIONS
Your heater comes with a 48-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
1
We expressly dismiss all other claims for damages, including consequential
damages.
2
Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
3
The warranty shall no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.
4
The warranty shall not apply to parts that are subject to normal wear, such as
the burner mat and the manual fuel pump.
5
The warranty shall only apply, when you present the original, dated proof of
purchase, provided no changes have been made to it.
6
The warranty shall not apply to damages caused by actions not in compliance
with the Directions for Use, neglect, and the use of an incorrect type of fuel,
or fuel past its use-by date. The use of incorrect fuel can even be dangerous*.
electrical
Dimensions (mm)
width
paraffin
(including base plate) depth
4.65
height
1.45
Accessories
manual fuel pump
75-190
transportation cap
0.484
Mains
*
388
-- AC/50 Hz
*
15.7
Electrical consumption igniter
*
continuous
13.5
Fuse rating
250V, 5A
level (NDIR CO
-sensor E-Guard T).
2
2
** Specified values are indicative
4
83
550
328
445
230V
320 W
26W
16-05-11 10:39

Publicité

loading