General Information; Electrical Connection - Resol SBS 2000 Manuel Pour Le Technicien Habilité

Station de rinçage et de remplissage
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

For solar thermal professionals, filling and flushing
solar thermal systems is a day-to-day business. The
RESOL SBS 2000 is the ideal companion for a profes-
sional performance – and the safe, quick and clean way
to complete filling and flushing work.
• Robust and durable
• Easy handling and cleaning
• Suitable for water, heat transfer and cleaning fluids
• Ergonomic design and top quality
• Also suitable for heating systems
• Integrated filter at the pump intake
Technical data
Dimensions: H × W × D = 1000 × 400 × 530 mm
Weight: 21 kg
Tank: 30 litres, PE, with dirt filter
Delivery flow: 5-47 l/min
Delivery height: 42 m
Pump power: 550 W (230 V~, 50 Hz)
Pump pressure: 4.2 bar
Drain valve: ½"
Hose connections: 3/4" union nut
Medium: Water, water-glycol mixtures
cleaning fluids for solar thermal systems
Medium temperature: max. 65 °C
Version
DE
Article no.
280 010 90
Pump
230 V~ / 50 Hz
Connection
Safety connection
Pump pressure
4.2 bar
when operated at 50 Hz
*
1

general information

The SBS filling and flushing station is only suitable for
water, water-glycol mixtures and cleaning fluids for
solar and heating systems. The medium must be free
of grit, but may be polluted. Dirt in the system is held
back by the filter situated at the pump intake inside
the tank.
UK 230 V~
UK 115 V~
280 010 93
280 011 93
230 V~ / 50 Hz
115 V~ / 60 Hz
UK plug
UK plug
4.2 bar
4,2 (3
*
) bar
The user must make sure that the SBS 2000 filling and
flushing station is suitable for the fluid in use.
WArnIng!
ATTEnTIOn!
ATTEnTIOn!
WArnIng!
2

Electrical connection

US
The cross-section of the connection cable must be at
280 010 97
least 1.5 mm².
115 V~ / 60 Hz
note
US plug
For your own safety: only use the filling and
flushing station in an electrical circuit fused
4.2 bar
by a residual current device.
risk of fatal injury by explosion
or deflagration!
Using the station with substances hav-
ing a flashing point lower than 55 °C
can lead to explosions or deflagrations.
Î Do not use the station with
petrol, solvants or other
volatile substances!
Pressure surge damage!
If the medium enters strongly heat-
ed, empty collectors, pressure surges
can occur.
Î Do not fill or flush the sys-
tem during times of strong
irradiation!
Damage to the device through
overheating!
During operation, the pump motor can
reach a temperature of up to 70 °C.
Î Make sure the air supply for
motor cooling is not blocked!
risk of scalding through over-
heating!
During opera tion, the pump mo-
tor can reach a temperature of up
to 70 °C.
Î Do not touch the heated
pump!
11