Descaling

The tank must be flushed after every use.
To prolong its service life and to reduce the need for manual decalcification we recommend that steam generators
are connected to a water softening filter, which removes the calcium. This is especially important if the water
hardness exceeds 7° dH (German hardness).
The water softener must not generate foam or produce harmful chemicals, which may give erroneous view of the
water level in the tank and cause the temperature switch to trip. (Heating elements will break down after some time.)
Manual descaling should be performed according to the chart below.
In normal private use, the need for descaling is minimal if the water is not particularly hard. However, the steam
generator must be descaled at least once a year. This removes the limescale from the tank walls and heating
elements.
Warning: The inlet pipe nut may be hot.
Steam generator descaling
Start the steam generator and let it run until the water in the tank boils.
Stop the steam generator and wait for about 5 minutes.
Remove the connecting piece's lid nut at the top of the steam generator.
WARNING: The nut on the lid might be hot – risk of burning.
Pour the descaling agent (e.g. citric acid) into the tank via the connecting piece using a funnel.
Attach the lid nut to the connecting piece and let the agent work abot 1 hour
Empty and rinse the tank until it is clean. The steam generator is now ready for use again.
Citric acid is an odourless and harmless descaling agent and it does not harm the steam generator's components.
If any other type of descaling agent is used, you must not bathe during the descaling procedure.
As can be seen from the adjoining chart, the need for manual descaling depends on water quality, steam generator
output and operation time.
Operation time in hours before descaling is required. A water softener must be used in public facilities
to reduce the need for manual descaling. . An electric drain valve can also be installed (Automatic drain
valve, sold separately).
Steam generator
output kW
3.4 kW
4.5 kW
6.0 kW
7.7 kW

Cleaning the steam room

Rinse the seats and the floor with warm water after every use (do not use a pressure washer). Clean the seats
regularly with mild detergent Use ethyl alcohol or dilutine. Never use abrasives, strongly alkaline detergents or
solvents to clean the steam room seats and walls. Contact the manufacturer if necessary.
It is important to clean the floor carefully all the way to the corners. Use hot water, a brush and floor detergent that
removes dirt and grease.
Amount of descal-
Softened water
ing agent. Citric
acid (1 bag 50g)
0.01 – 1° dH
2 bags
7000
2 bags
3800
2 bags
2600
2 bags
1700
Hours of operation, different hardnesses
Soft water
Medium-hard
water
4–7° dH
1–3° dH
2300
900
1300
500
900
300
600
200
6
Hard water
8–14° dH
350
190
130
90