Summary Table Of Technical Data - LEGALLAIS HB300 Manuel De Mise En Service, D'opération Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

____________________________________________EN________________________________________5
The current of the electric system has to be connected to the hot water tank
through an all-pole disconnection device, which has at least 3mm separation
distance in all poles. This separator equipment must to connect in fixed grid
wiring.
For personnel authorízed to perform the maintanance and change of the electric
wiring system of the appliance to avoid any electrical shock. Only manufacturer
or the authorized service or simmilar skilled budies can do this kind of
maintenence ont he appliance.
2.1.

Summary table of technical data

Sizes: diameter/height/depth
Water pipeline connection
Circulation pipe branch connection
Rated volume
Rated operation pressure
Safety valve max. opening pressure
Largest water supply pressure
Smallest required network pressure
Standby energy use at 60
Weight
Type
Air duct connection (inlet/outlet)
Condenser
GWP / Cooling agent / quantity
Max. Power Consumption
Average Power Consumption
Air flow
Reachable static pressure
External static pressure range where the appliance has been
examined
Max. suction side pressure
Max. blow side pressure
Minimum space required for operation (in case of operation without
air duct
Operation temperature range
Max. water temperature
o
COP 15/10-55
C
EN-255-3
COP 7/10-55°C
EN-16147
Noise level
Type of outlet air
Heatable volume
Voltage/frequency
Fuse
Rated heating performance
Largest electric power consumption
Heating time
Max. water temperature
Min. Water temperature
Heat insulation/thickness
Tank
QUALITY CERTIFICATION LABEL-TECHNICAL DATA
Type
o
C
Heat pump
Air support flowing vertically upward
Electric heating
Others
Freon free PUR insulation / 50 mm
HB300
Ø661/1930/720
G3/4
G3/4
295 l
0,6 MPa
0,7 MPa
0,525 MPa
0,01 MPa
2500 Wh/24h
124 kg
air (indoor)
Ø190 mm
safety heat exchanger
1300 / R134a / 1100 g
1200W
850W
3
~500m
/h
80 Pa
1013 – 1050 hPa
1,0 MPa
2,5 MPa
3
20 m
o
-7 - +43
C
o
60
C
3,5
2,1
48 dB(A)
100 l
L/N/PE 230V~ / 50Hz
5A/250V~(T)
1800W
16 A
3,5 h
o
60
C
o
10
C
Enamelled steel sheet