Installation • Operation • Maintenance
Follow these guidelines for installation:
1. Provide properly sized sump (see Specifications).
2. Do not set pump directly on the bottom of sump pit
if it is not solid. Raise the pump by using bricks or
concrete blocks underneath it.
3. Make sure sump is free of string, cloth, nails, gravel,
etc. before installing pump.
4. Do not remove ground pin from electrical plug.
5. Do not use an extension cord to operate this pump.
6. For proper automatic operation, make sure the pump
power cord is plugged into the piggyback receptacle
on the switch cord. Three phase models must be
properly connected to a suitable control panel.
Do not cut, crimp, or bend single phase switch
power cord (15). The vent tube needs to "breathe"
for proper operation of switch. This may cause pump
failure and void warranty.
7. Use steel or plastic pipe for all connecting lines
between pump and sewer outlet.
NOTICE: Some city regulations do not
allow installing a pump with plastic pipe.
Check local regulations.
8. Use PTFE pipe thread sealant tape on pipe
connections. Do not use ordinary pipe joint
compound on plastic pipe or pump. Pipe joint
compound can attack plastics and damage pump.
9. In applications where the pump may sit idle for
months at a time, it is recommended that the
pump(s) be cycled every month to ensure the
pumping system is working properly when needed.
10. A check valve should be installed horizontally in
discharge pipe.
11. The optional Hydromatic Q Alert is an audible
alarm system for high water conditions. It should be
installed in every sump for greater protection.
NOTICE: Q Alert is for indoor use only. Other Q
Alarm and control panels are available for outdoor
use. Contact your HYDROMATIC distributor
for applications.
12. Use pump partially or completely submerged for
pumping waterlike liquids. The pump will pump
solid materials up to 2" (spherical) in diameter.
Risk of fire. Do not pump flammable
liquids. Strong chemicals or salt water should not
be pumped without consulting your HYDROMATIC
distributor for proper seals and coatings.

Operation

NOTICE: Do not allow pump to run in a dry sump.
Doing so will void the warranty and may damage
the pump.
An automatic overload protector in the motor will
protect the motor from burning out due to overheating/
overloading. When the motor cools down, the overload
protector will automatically reset.
If overload trips frequently, check for the cause. It could
be a stuck impeller, wrong/low voltage, or electrical
failure in motor. If an electrical failure in the motor is
suspected, have it serviced by a competent repairman.

Maintenance

Read the following instructions carefully before replacing
any parts. Reasonable care and safe methods should be
practiced. Check local codes and requirements before
installation. Only a competent plumber/electrician
should make the installations.
Submerge pump in a disinfectant solution (dilute chlorine
bleach) for at least one hour before disassembling pump.
Check for an obstruction in the impeller by looking
through the suction hole of the pump. The shaft should
turn freely if unobstructed. Keep fingers, clothing or any
material from suction inlet.
The steps described in this section should be performed
only by an authorized service center.
NOTICE: Read all directions before replacing any
parts. Remove pump and switch from power source
before servicing.
The numbers in parentheses, such as "(3)" or "(16)", refer
to item numbers used on the Repair Parts diagram.

Replacing diaphragm switch

From switch housing (15) remove screw (14) from
housing. Replace with new switch. Insert screw (14) into
housing (15) and tighten. Plug pump power cord into
the piggyback receptacle on the switch cord, and then
switch plug into correct power source.
Checking motor operation
Plug power cord directly in power source to check motor
operation. Motor should start and run smoothly. If motor
does not start, pump must be dismantled and motor
checked. Be certain to unplug cord before disconnecting
any wires.