Fisher & Paykel CG122 Instructions D'installation Et Guide D'utilisation page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gas connection specifications
Refer to the 'Safety and warnings' section for additional gas connection specifications.
Flexible hose connections
If local codes permit, CSA design-certified, flexible metal appliance connector is recommended
for connecting this cooktop to the gas supply line. Do not kink or damage the flexible connector
when moving the cooktop. The gas pressure regulator has 3/8" NPT female pipe threads. You will
need to determine the fittings required, depending on the size of your gas supply line, flexible
metal connector and shut-off valve.
Rigid pipe connections
If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an
in-line connection to the cooktop. All strains must be removed from the supply and fuel lines so
the cooktop will be level and free of pressure from the piping.
Use joint compounds and
washers resistant to the action
of all gas types on all male
pipe threads.
Do not overtighten the gas
fitting when attaching it to
the gas pressure regulator,
as doing so may crack the
regulator.
Screw
Unscrew
Fig. 12 Checking the manifold pressure
Elbow
connection
1/2" G cylindrical
(ISO 228-1) male
Washer
Extension
Extension
pipe female
pipe female
pipe fitting
pipe fitting
Extension
pipe male
pipe fitting
Washer
3/8" NPT (conical)
male
Pressure
regulator
To cooktop
Manifold
test point
pressure
1/8" NPT
To mains
connection
Installation instructions
Washer
Manifold female pipe fitting
1/2" G cylindrical
(ISO 228-1) female
Extension
pipe
1/2" G cylindrical
(ISO 228-1) male
1/2" G cylindrical
(ISO 228-1) female
Connector
3/8" NPT
female
3/8" NPT
female
WARNING: check that the gas pressure
regulator is correctly positioned.
The arrow on the back of the gas
regulator must be oriented toward the connector.
Cooktop
manifold
To cooktop
Manifold
test point
pressure
1/8" NPT
To mains
connection
Arrow
Fig. 13 Gas connection