PROPER VENTILATION REQUIREMENTS

6
US
CA
IMPORTANT INFORMATION:
CAUTION!
Ventilation hoods and blowers are designed for use with single wall ducting. However, some local building codes
or inspectors may require double wall ducting. Consult local building codes and/or local agencies before starting,
to ensure that hood and duct installation will meet local requirements. Hood blower speeds should be variable
to reduce noise and loss of heated or air conditioned household air when maximum ventilation is not required.
For best smoke elimination, the lower edge of the hood should BE INSTALLED A MINIMUM OF 30" TO A MAXIMUM
OF 36" ABOVE THE COOKING SURFACE. If the hood contains any combustible materials (ie a wood covering)
it must be a minimum of 36" above the cooking surface. Due to a high volume of ventilation air, a source of
outside replacement air is recommended. This is particularly important for tightly sealed and insulated homes.
A reputable heating and ventilating contractor should be consulted.
VENTILATION REQUIREMENTS:
STANDARD COUNTER INSTALLATION RECOMMENDATIONS
HOOD:
(23" Deep x Unit Width)
BLOWER: 30"/36" COOKTOPS
600 CFM min.
non-combustible surface ,
18" Min. clearance to
combustible surface
combustible surface – from
from side of cooktop
outer edge
Δ AS DEFINED IN THE "NATIONAL FUEL GAS CODE" (ANSI Z223.1, LATEST EDITION).
THE HORIZONTAL SURFACES OF THE RANGE TOP (COOKTOP) TRIM MUST NOT BE
BELOW COUNTERTOP LEVEL.
NOTE: SEE MANUFACTURER'S RECOMMENDATIONS FOR DUCTING SPECIFICATIONS.
30" Min. clearance to
36" Min. clearance to
cooking surface
COOKING SURFACE