INSTALLATION INSTRUCTIONS

10
US

CUTOUT AND CABINETRY DIMENSIONS

CA
A
C
*
Non-combustible surfaces
as defined in 'National Fuel Gas Code' (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and
are not certified by UL. Clearances must be approved by the local codes and/or by the local authority having jurisdiction.
Note: See manufacturer's recommendations for ducting specifications.
WHEN INSTALLING WITH A Fisher & Paykel DD-36 OR DD30 DOWNDRAFT VENTILATION SYSTEM
G
A
H
C
* Non-combustible surfaces
as defined in 'National Fuel Gas Code' (ANSI Z223.1, Current Edition). Clearances from
non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by UL.
Clearances must be approved by the local codes and/or by the local authority having jurisdiction.
Notes:
- See manufacturer's recommendations for ducting specifications.
- The horizontal surfaces of the cooktop trim must NOT BE below countertop level.
- When installing a 30" Cooktop with a Downdraft (DD-30SS), a minimum of a 26" cabinetry depth
is required.
WHEN INSTALLING WITH A RANGEHOOD
F
B
G
E
H
I
K
B
E
F
J
I
D
electrical
and
gas supply
A) 18" MIN.
B) 13" MAX.
CAUTION:
C) 12" MIN. TO COMBUSTIBLES FOR ALL MODELS
36" min. to
combustible
D) 19-3/4" DEPTH
material ,
from cooking
E) 34-3/4" FOR CDV2-365 MODELS
surface
28-5/8" FOR CDV2-304 MODELS
D
F) 36" HOOD WIDTH MIN. FOR CDV2-365 MODELS
30" HOOD WIDTH MIN. FOR CDV2-304 MODELS
G) 7" TO COMBUSTIBLES FOR ALL MODELS
H) 5"
electrical
and
I)
18"
gas supply
A) 18" MIN.
B) 13" MAX.
CAUTION:
36" min. to
C) 12" MIN. TO COMBUSTIBLES FOR ALL MODELS
combustible
material
,
*
D) 19-3/4" DEPTH
from cooking
surface
E)
34-3/4" WIDTH FOR CDV2-365 MODELS
28-5/8" WIDTH FOR CDV2-304 MODELS
F)
33-1/2" WIDTH FOR DD36
27-1/2" WIDTH FOR DD30
G) 1/2" MIN. TO COMBUSTIBLES FOR ALL MODELS
H) 2-5/8"
I)
9"
J)
26-1/2"
K) MIN. 36" FOR CDV2-365 MODELS
MIN. 30" FOR CDV2-304 MODELS