Stand-Alone Operation Check - Tabuchi Electric EneTelus EHW-S55P3B-PNUS Manuel D'installation

Masquer les pouces Voir aussi pour EneTelus EHW-S55P3B-PNUS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Stand-alone Operation Check

Confirm that the DC Switch-Disconnector on the outside of the inverter, the grid-tied breaker in the home breaker box, the
breakers in the back-up breaker box, and the switch inside the storage battery unit are the OFF position. Activate power as
explained in the following procedure.
Supplying power to improperly connected wires will damage the inverter or storage battery unit.
(Service required as a result of incorrect wiring or improper installation will be subject to billing.)
1
Check wiring to the solar panels.
CAUTION
① Confirm that there is a sufficient amount of sunlight.
② Connect the cable between the solar
panels and the inverter.
③ Confirm the voltage to all solar panel input
terminals is as written in the box below.
Measure voltage at the test points shown
in the picture on the left.
(Pay attention to polarity.)
Voltage between N terminal (-)
and P terminal (+):80 to 450 V DC
2
Activate and check the power of the storage battery unit.
① Confirm that the [+] and [-] cables are not shorted, turn
the tab to open the switch cover and set the switch inside
the storage battery unit to the ON position.
② Confirm the green LED operation light on the
storage battery unit is lit.
③ Confirm the voltage to the storage battery unit terminals
inside the inverter is as written in the box below.
Measure voltage at the test points as shown in the picture below.
(Pay attention to polarity.)
Voltage between P terminal (+)
and N terminal (-):60 to 95 V DC
Test Points
24
Do not set the DC Switch-Disconnector on the inverter to the ON position yet.
Test Points
REQUIRED
Switch Cover
Tab
WARNING
Do not short the [+] cable (black)
or [-] cable (white) of the storage
battery unit.
Shorted cables may damage the
storage batteries and result in fire or
electric shock.
OPERATE
MODE
ALARM

Publicité