The menu is organised on three levels, as shown in the previous figure.
To scroll through items within a level, use the ↑ and ↓ keys.
To enter the selected menu, press
Unless otherwise specified,
in menus with two levels, press the
in menus with three levels, press the
Pressing and holding
'HOME' M
ENU
This is the inverter default menu and displays information of immediate interest on the first line:
„Pac‟: The active power fed to the grid
„Qac‟: The reactive power exchanged with the grid
„PF‟: The power factor
'Eday': Energy produced on the current day
'Etot': Total energy produced
„Hday‟: Hours of operation on the current day
„Htot‟: Total hours of operation
Current status: one of the status conditions described in the Operation logic paragraph.
„ LAST STOP INFO‟: reason for the last feeding interruption.
The system clock and any error messages are displayed on the second line.
During the verification phases before grid connection, the menu automatically switches to current status mode. Once feeding has
started, it displays the active power fed to the grid.
Despite the fact that the inverter has been designed according to the most accurate technological standards,
it cannot be regarded as a measuring instrument. A deviation of the energy values shown by the input meter
compared to the inverter is normal.
'MEASURES' M
ENU
This menu shows the electrical inputs and outputs of the inverter in detail:
Input screens:
instantaneous values:
„DC1 xxx.xV xx.xA‟:
„DC2 xxx.xV xx.xA‟:
maximums recorded:
„DC1
Wmax‟:
„DC2
Wmax‟:
On inverters with a single MPPT tracker, the line „DC2‟ is not present and the only line present shows the message „DC‟.
Output screen:
„AC xxx.xV xx.xA‟: This line shows the instantaneous values of the mains voltage and the current emitted to the grid.
„XxxVavg xx.xxHz‟: This line shows the average mains voltage of the last 10 minutes and the instantaneous grid
frequency.
..
button on level 2 to return to level 1;
button on level 3 to return to the level 2 menu „exit‟ screen.
(for more than 1.5 s) will return the user to the „home menu‟.
this line describes the MPPT1 status
this line describes the MPPT2 status
This line shows the maximum power value recorded by MPPT1 on the current day
This line shows the maximum power value recorded by MPPT2 on the current day
- 51 -