Setting Priming Time

Filter Menu

Clean Filter Pressure
®
Filter
12:15
1 bar
1 bar
Clean Filter Pressure
Press
Select
to access Max Priming Time.
Press
Left arrow
and
Right arrow
Change values by pressing
Up arrow
When value is set, press
Enter
Note: The "System Priming Time" menu should only be used when excessive amounts of air need
to be evacuated from the system. IntelliFlo VF can prime in seconds, but additional time may be
needed to fi ll other devices – e.g., fi lters or solar heating systems.
Press
Down arrow
to scroll to Filter menu.
IntelliFlo VF is constantly monitoring fi lter pressure, and when it detects that the system needs
cleaning, an "Alert – Service System Soon" message will appear on the control panel display.
This parameter can be set from 69 to 3448 mbar, and establishes when the "Service System Soon"
alert will activate. Average setting should be between 690 and 1380 mbar for most pools and fi lters.
Note: mbar changes can come from anywhere in the system, e.g., clogged skimmers or pump strainer
baskets. Note: Initial start-up and installation of the IntelliFlo pump must always be performed with a
clean fi lter. If the fi lter has been in use, run the fi lter backwash cycle before start-up.
Press
Select
to access Clean Filter Pressure setting.
Press
Left arrow
and
Right arrow
Change values by pressing
Up arrow
When value is set, press
Enter
to select digit to modify.
and
Down
arrow.
to confi rm value and save changes.
to select digit to modify.
and
Down
arrow.
to confi rm value and save changes.
9