Télécharger Imprimer la page

Backwash Menu - Pentair Water Pool and Spa IntelliFlo VF Variable Flow Guide De Démarrage Rapide

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55

Backwash Menu

Setting Backwash Flow
Features – Modulated Output and Backwash
The Backwash mode is initiated by pressing the Backwash button.
(The Backwash button doubles for rinse during operation.) A Rinse cycle is automatically executed
after the Backwash cycle. IntelliFlo will display a "Filter Warning" or "Service System Soon" message
when the fi lter needs to be cleaned. Before operating, you need to set the Backwash Flow and
Duration, and Rinse Duration.
Note: When using cartridge fi lters, the backwash cycle must be performed when cleaning or
replacing fi lters. When charging a D.E. system, charge the system fi rst during a normal running cycle.
After the fi lter is charged, run backwash mode with the fi lter valve in the fi lter position to reset the %
clean fi lter status. Then run the pump in fi lter mode.
Always perform Backwash before initial start-up and installation to ensure most
effi cient system performance.
Press
Menu
and
Up arrow
Press
Select
to display Backwash Flow.
Press
Select
to access setting.
Press
Left arrow
and
Right arrow
Change values by pressing
Up arrow
When value is set, press
Enter
or
Down arrow
to select Backwash menu.
to select digit to modify.
and
Down
arrow.
to confi rm value and save changes.
15

Publicité

loading