Sears CRAFTSMAN 919.728000 Manuel D'instructions page 16

Compresseur d'air monté sur réservoir
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROBLEM
Compressor is not supply-
ing enough air to operate
accessories.
Motor will not run or restart.
Regulator knob continuous
air leak. Regulator will not
shut off at air outlet.
D21245
CAUSE
Compressor is not large enough
for air requirement.
Restricted air intake filter.
Hole in hose.
Check valve restricted.
Air leaks.
Loose belt.
Restricted or defective check valve.
Present tank pressure exceeds
pressure switch "cut-in" pressure.
Fuse blown, circuit breaker tripped.
Motor overload protection switch
has tripped.
Possible defective motor or
capactior.
Paint spray on internal motor
parts.
Check valve stuck open, putting
pressure on head.
Pressure release valve on pressure
switch has not unloaded head
pressure.
Dirty or damaged regulator
internal parts.
16 — ENG
CORRECTION
Check the accessory air requirement. If it is higher
than the SCFM or pressure supplied by your air
compressor, you need a larger compressor.
Clean or replace air intake filter. Do not operate
the air compressor in any paint spray or drywall
sanding area.
Check and replace if required.
Remove and clean, or replace.
Tighten fittings.
Adjust belt tension.
Remove and clean or replace.
Motor will start automatically when tank pressure
drops below "cut-in" pressure of pressure switch.
1.
Check fuse box for blown fuse and replace, if
necessary. Reset circuit breaker. Do not use a
fuse or circuit breaker with higher rating than
that specified for your particular branch circuit.
2.
Check for proper fuse; only Time Delay fuses
are acceptable.
3.
Check for low voltage conditions and/or
proper extension cord.
4.
Disconnect the other electrical appliances
from circuit or operate the compressor on its
own branch circuit.
5.
Check for loose electrical connections.
Let motor cool off and overload switch will
auto- matically reset.
Return to Sears Service Center for inspection or
replacement, if necessary.
Have compressor checked at Sears Service Center.
Do not operate the compressor in the paint spray
area. See flammable vapor warning.
Remove and clean, or replace the check valve.
Bleed the line by pushing the lever on the pressure
switch to the "O" position; if the valve does not
open, replace it.
Replace regulator.

Publicité

Chapitres

Table des Matières

Dépannage

loading