3. INSTALLATION AND PREPARATIONS FOR USE

!
Important: This appliance must be installed by a qualified people according to the
manufacturers installation instructions, local building regulations, gas authority codes and
electrical wiring instructions.
3.1. Installation of your product

Advice for the installer

!
Important
• The appliance should be installed, regulated and adapted to function with other types of gas by
a QUALIFIED INSTALLATION TECHNICIAN. Failure to comply with this condition will render the
guarantee invalid.
• The appliance must be installed in compliance with regulations in force.
• Installation technicians must comply to current laws in force concerning ventilation and the
evacuation of exhaust gases.
• Always disconnect the gas supply from the appliance before carrying out any maintenance
operations or repairs.
• The appliance must be housed in heat-resistant units.
• These tops are designed to be embedded into kitchen fixtures measuring 600 mm in depth.
• The walls of the units must not be higher than work top and must be capable of resisting
temperatures of 60 °C above room temperature.
• Do not install the appliance near inflammable materials (eg. curtains).
Location
• The appliance may be installed in a kitchen, kitchen/diner or a bed sitting room, but not in a
room or space containing a bath or a shower.
• The appliance must not be installed in a bed-sitting room of less than 20 m .
• The appliance is designed and approved for domestic use only and should not be installed in a
commercial, semi commercial or communal environment. Your product will not be guaranteed if
installed in any of the above environments and could affect any third party or public liability
insurances you may have.

Ventilation requirements

• For rooms with a volume of less than 5 m - permanent ventilation of 100 mm free area is
required.