5. Fit the agitator through the belt, making sure the belt is aligned with
the pulley section of the agitator.
6. Lower the agitator into place, making sure that the oval shaped tabs fit
into the indents on the head.
7. Reinstall the agitator brush cover as described above.
For a replacement belt, order LG service center belt part
#MAS62064002.
Removing Clogs
WARNING
y Electrical shock and personal injury hazard.
y Always unplug the power cord from the electrical outlet
before servicing.
y Failure to do so could result in electrical shock or personal
injury.
If you notice a loss in suction, first check the filters as described on page
13. If the filters are clean, there may be a clog. The arrows show areas
where clogs are most likely to occur.
To Check for Clogs:
1. Check the hose where it connects to the handle by pressing the two
release buttons on the top end of the hose.
2. Remove the dust tank and check the dust tank inlet and body inlet
where it connects to the vacuum cleaner body.