Additional Clause to the Safety Regulations for Operating
the Explosion-Protected Truck Model (Ex)
Explosion-protected trucks are labelled as follows:
Trucks with this label can be used in zone 1 areas at risk from explosion due to gas,
steam or mist of explosion group IIB and temperature group T4. The lesser
requirements of zone 2 and temperature classes T3, T2 and T1 are also covered.
Trucks with this label can be used in zone 21 areas at risk from explosion due to
fibres, lint or electrically conductive dust. The maximum surface temperature of the
truck is 130 °C and the minimum ignition temperature must be at least 195 °C. The
smouldering temperature must be 205°C for a maximum truck surface temperature
of 130°C.
WARNING!
Dust, contamination and paint, acids and caustic solutions can cause a
reduction or complete failure of electrical/electronic energy conducted to the
ground.
The truck and transport routes must be treated accordingly.
The control of safety equipment, such as the function of the electrically conductive
wheels, is the sole responsibility of the user.
When replacing wheels always use functionally equivalent parts; at least one wheel
must be antistatic.
The truck must be moved in and out of the load handling opening, avoiding scraping
against sharp edges.
22
II 2G IIB T4 (Gas)
II 2D T130°C