LOCATING AND ASSEMBLING THE POWER BURNER
When determining a suitable location for your Power Burner, take into account concerns such as
exposure to wind, rain, sprinklers, proximity to traffic paths, and keeping any gas supply line runs
as short as possible.
EN
Locate the Power Burner only in a well-ventilated area. Never locate the Power Burner in a
building, garage, breezeway, shed or other such enclosed areas without an approved ventilation
system. Never locate the Power Burner over, under, or next to unprotected combustible
construction.
Using the Power Burner in windy areas can disrupt the flame, especially on low or simmer
settings. This may cause nuisance sparking of the igniters. Relocate to a less windy area. If the
Power Burner is mounted in an enclosure (island), you may need to build a wind-break to avoid
this issue in the future.
When installing a Power Burner or other gas appliance into an enclosure (island), the enclosure
must be constructed with ventilation openings to avoid accumulation of gas should there be a
leak. See the INSTALLATION section of this manual for details. Keep the area underneath the
Power Burner free of debris.
Ensure all packaging, straps, etc. have been
removed from the Power Burner. Remove any
tie-down wires from the burners.
Ensure that the burner cap is mounted correctly
on the center burner ring. Do not operate the
Power Burner without the burner cap in place
(see Fig. 1).
Figure 1

INSTALLATION

CLEARANCES:
TO NON-COMBUSTIBLE CONSTRUCTION
A minimum of 4" (10 cm) clearance from the sides and back of the Power Burner to non-
combustible construction is required. This is especially important when cooking with large
diameter pots.
TO COMBUSTIBLE CONSTRUCTION
This appliance must be installed in a NON-COMBUSTIBLE ENCLOSURE (ISLAND) ONLY. It
should NOT be installed on, over, or next to unprotected combustible construction. Do not
use this appliance under unprotected overhead combustible surfaces. The countertop, and
everything under the countertop must be of non-combustible materials. A minimum clearance to
vertical combustible material is 9" (23 cm) on the sides and the rear of the appliance.
As an example, if you have an island with a stucco or tiled surface and wood-frame construction
beneath, the wood is considered combustible, even though the Power Burner is touching the
stucco or tile surface, which is non-combustible. In extreme circumstances, the wood could
potentially get hot enough to burn. Therefore, ALL the construction must be non-combustible.
Adjacent walls above the cooking surface should also be non-combustible. If those adjacent
surfaces are made of combustible material, they must be outside this 9" (23 cm) zone. The Power
Burner has a very high output, and if installed in a confined area with a large pot on top, the
potential to heat up adjacent surfaces is dangerous and could result in property damage.