1 1
1 Make the orifice (A), 10.5 mm in diameter, 5 cm from
the centre of the shutter. Remember that the cover
(1) of the limit switches must be accessible for
connections and subsequent adjustments.
3 Fasten the two halves of the operator using the
corresponding M8 screws. Use a 6 mm Allen key.
5 Position the roller bands (7) and the two semi-crowns
(8) and secure them using the corresponding M8
screws.
8
7 Move the cam by hand, bringing it up to the limit
switch [2] (down). If the operator has been installed
in opposite direction, the "down" limit switch is [1].
10
5 cm
P270A
P270C
7
P270F
2
1
P270H
Assembly
2 Place the two halves (2) and (3) of the operator on
the shaft, ensuring that the screw (4) is inserted in the
orifice (A).
If the diameter of the shutter shaft is less than 60 mm,
position the adapter bushing (5).
5
4 Adjust the operator to the shaft, locking it using the
screw with nut (6).
6 Position the final shutter slat and make the fastening
orifice (B), 10.5 mm in diameter.
8 Fasten the slat on the crown using the screw and
corresponding washer. Use the diameter adapter (9)
if necessary.
9 Make an orifice (C) in the shutter shaft in order to
introduce the electrical cable, ensuring it does not
come into contact with the moving parts.
3