Instructions for mode of operation/ voltage supply
X
In case of closed circuit current lockings, set the DIP switch on the controller to
X
the "Opener" mode of operation. Then disconnect the controller briefly from the
power supply.
Use separate power supply for 24 V variants for the holding magnet/ door opener.
X
X
In 12 V variants, the supply can be provided via the SmartOpen power supply.
Ensure maximum current consumption.
Commissioning
GCER 100 identifies only RFID identification mediums in the 125 kHz range. If the
medium is not identified, check the frequency range if necessary.
it must be checked whether a transponder is integrated (car keys of Mercedes gene-
rally do not have an integrated transponder).
Successful readiness of the system is signalled by the permanent blue lights of its
LED after connecting the voltage supply to the reader
Function Action
X
Program-
X
Holding the master car just in
ming the
front of the reader (max. 5 sec.)
new
X
X
Remove master card
identifica-
X
Hold the new identification in
tion /
X
keys
front of the reader (5-10 sec.)
If the master card is inadvertently held before the reader for a very long time (more
than 15 sec.) while "programming" or "individual deletion", the LED increasingly flashes
red and switches to the "Delete all" mode. In order to avoid the deletion of all the
already programmed identifications, remove the card immediately and wait until the
reader no longer flashes and the blue LED lights permanently (approx. 45 sec).
X
Dele-
X
Hold the master card for more
ting an
than 5 sec. in front of the
individual
reader
identifica-
X
X
Remove master card
tion /
X
X
Hold the identification to be
key
deleted in front of the reader
X
Deleting
Hold master card for more
X
all
than 15 sec. in front of the
identifica-
reader
tions /
keys
X
X
Remove master card
If a key or transponder is lost, the entire memory must be deleted for safety
reasons. Then re-programme all the existing keys
Feedback
à LED flashes blue slowly
à LED flashes blue slowly
à LED lights blue permanently
à Output at the controller connects (not audible). If an
identification is not identified, the LED continues to
flash slowly (45 sec.)
à LED flashes blue slowly (0-5 sec.)
à LED flashes red slowly (after 5 sec.)
à LED flashes red slowly
à LED lights blue permanently
à Output at the controller no longer connects.
à LED flashes blue slowly (0-5 sec.)
à LED flashes red slowly (after 5-10 sec.)
à LED flashes red fast (after 10-15 sec.)
à LED goes out
à LED remains off for 5 sec.
à LED lights blue again permanently
.
GB | ENGLISH