 Blue Bulk LED and Green Equalization LED both flashing.
 A well proven process that carefully equalize the battery to store it's full
capacity, the Equalization stage for Calcium battery selection is automatic.
The equalization stage for AGM & WET and GEL battery only occurs if the in
Initial start voltage is below 11 Volts.
o Analysis Mode ( Battery retention test Mode)
 The charging is interrupted for a short period for battery voltage measured
 If the battery voltage falls too quickly, the battery is probably faulty.
 The Green Full LED is FLASHING (if above situation occurred)
o Float Mode (Safe voltage level of 13.2V)
 Full Green LED is ON.
 The Float Mode allows the charger to effectively be left connected to your
batteries; it works at a safe level of 13.2V, and ready for use.
STEP 4 - Disconnecting the Battery charger from Battery
 If the Battery is out of the vehicle.
o Switch OFF and Remove the AC Power Plug from the outlet.
o Remove the Black lead and then the Red lead.
o Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)
 If the Battery is in the vehicle.
o Switch OFF and Remove the AC Power Plug from the outlet.
o Remove the lead from the vehicle chassis.
o Remove the lead from the battery.
o Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)
LED STATUS INIDICATOR TABLE: