The following steps can be done with or without someone in the wheelchair:
Depth and Angle Adjustments:
1. Loosen the two Cane Bracket Adjustment Screws and adjust for desired level of depth and angle. Only loosen
adjustment screw 3/4 of a turn to slide. Do not disconnect from the attached unit. Fig. C
2. Use reference marks on the top of the Holster to make incremental adjustments.
3. Adjust the hardware on both Cane Brackets before fully tightening the adjustment screws.
4. Tighten the two Cane Bracket Adjustment Screws to maintain the adjustment.
Horizontal Shell Bracket Adjustment:
1. Loosen the two Slide Bracket Screws.
2. Make lateral Shell adjustments.
3. Retighten the screws.
SLIDE BRACKET
SCREWS
(Horizontal
Adjustment)
For additional hardware configuration options, see the Technical Guides available at www.VARILITE.com.
Back Support Operation
REMOVAL
1
2
*
INSERTION
1
2
PERMANENT MOUNT INSTALLATION
1. Loosen the left and right Slide Bracket Screws.
2. Install the Permanent Mount Screw using the 3-32 in. hex key through the Permanent Mount Hole into the Slide Bracket.
3. Tighten the left and right Slide Bracket Screws.
CUSHION SETUP AND ADJUSTMENT:
Inflating Cushion:
1. To inflate cushion, remove load from cushion.
2. Open air valve by turning valve counterclockwise.
3. When cushion is fully inflated, close air valve by turning valve clockwise.
Adjusting Cushion:
1. To adjust the air level of the VARILITE back support cushion, begin with the cushion fully inflated and the valve closed.
2. Position yourself securely in your wheelchair.
3. Turn the valve counterclockwise to open the valve and release air.
4. Close the valve when the most comfortable and supportive position is achieved.
Removing Cushion:
1. Pull the cushion up to detach the cover from the shell.
2. Detach the handle flap from the handle patch inside the shell and pull the flap through the slot in the shell.
Vertical Shell Bracket Adjustment:
1. Loosen the two screws on each Shell Bracket.
2. Make vertical Shell adjustments.
3. Retighten the screws.
SHELL BRACKET
SCREWS
(Vertical
Adjustment)
3
3
4
CANE BRACKET
ADJUSTMENT
SCREWS
*NOTE: When
Permanent Mount
Screws are
engaged, Slide
Brackets cannot be
removed from the
Holster
AIR
VALVE
Fig. C
COVER
HANDLE
HANDLE FLAP
AND SHELL SLOT