ELECTRICAL GROUNDING INSTRUCTIONS: (continued)

DUTY CYCLE:

To ensure long life of your BOSTITCH air compressor, do not operate on more than a 50% duty cycle. If this
air compressor pumps air more than 50% of one hour, then the compressor's capability is less than the air
delivery required by the application. Always match the air volume requirements of the attachment or
accessory with the air volume delivery of the compressor.
NOTICE!: BOSTITCH does not recommend the use of extension cords with compressors. The use of an
extension cord can result in the loss of voltage supplied to the compressor which could prevent the
compressor from starting. For optimum performance, plug the compressor directly into an outlet and
increase the length of airline as needed.
If an extension cord must be used, use these guidelines:
Distance Needed . . . . . . . . . . . . . . . . . . . . . Recommended Gauge
Less than 25 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Gauge
25 - 50 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Gauge
Greater than 50 ft. . . . . . . . . . . . . . . . . . . . . . . . Not Recommended
CAP2560OL
Motor:
Fuse Requirements:
Operating Pressure:
Safety Valve Setting:
Displacement:
Air Delivery:
Maximum Amps at Working Pressure:
Tank Size:
Air Outlet:
Pressure Switch Settings:
Weight:
PSI = Pounds Per Square Inch:
SPECIFICATIONS
2.5HP Peak
1.5HP Running
115V – 60HZ
15 Amps minimum
0 – 135 PSI
150 PSI
4.9 CFM @ 40 PSI
3.6 CFM @ 90 PSI
14 Amps
6 Gallons
1/4" NPT
On @ 105 PSI
Off @ 135 PSI
49 lbs.
CFM = Cubic Feet Per Minute