Model
DVC(C,P)32BP3(-3,-4)
DVC(C,P)36BP3(-3,-4)
This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other
qualified agency¹)* in accordance with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
National Fuel Gas Code Z223.1 (Latest Edition)
1
*The term "qualified agency" means any individual, firm, corporation or company which either
in person or through a representative is engaged in and is responsible for (a) the installation
of gas piping or (b) the connection, installation repair, or servicing of equipment, who is
experienced in such work, familiar with all precautions required, and has complied with all the
requirements of the authority having jurisdiction.
Perform the safety shutdown test any time work is done on a gas system to avoid the possibility
of fire or explosion with property damage, personal injury or loss of life.
CHECK SAFETY SHUTDOWN SYSTEM
Continuous Ignition Systems (Standing Pilot)
1. Place gas control knob in PILOT position. Main burner should go off and pilot should remain lit.
2. Extinguish pilot flame. Pilot gas flow should stop within 30 seconds. Safety shut-off of pilot gas proves complete
shutdown since safety shutoff valve blocks flow of gas to main burner and pilot.
3. Relight pilot burner and operate system through one complete cycle to make sure all controls operate properly.
Part Description
Pilot Orifice
Main Burner Orifice
SIT Gas Valve Conversion Kit
Gas Conversion Label
Tools Needed: Standard Screwdriver, 1/4" Hex Driver, 5/16" Hex Driver, 3/8" and 7/16" Wrenches
41317-1-0220
GAS CONVERSION INSTRUCTIONS
DIRECT - VENT GAS FIREPLACE
CONVERSION KITS
Part No.
31768
31770
FOR CONVERSION TO PROPANE GAS
CHECK THE SAFETY SHUTDOWN PERFORMANCE
Conversion Kit
31768
R7658
P204
R7657
2139
Empire Comfort Systems Inc. • Belleville, IL
Model
DVC(C,P)42BP3(-3,-4)
WARNING
WARNING
PARTS LIST
Conversion Kit
31770
R7658
P208
R7657
2139
Conversion Kit
Quantity Supplied
31772
R7658
P258
R7657
2139
Part No.
31772
1
1
1
1
Page 1

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems DVC32BP3

  • Page 1 FOR CONVERSION TO PROPANE GAS WARNING This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other qualified agency¹)* in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage.
  • Page 2 12. Pull upward on pilot hood to remove and gain access to pilot injector orifice. If fireplace is not installed or warranty card has not been 13. Remove Natural Gas pilot injector orifice from pilot returned to Empire Comfort Systems, Inc., check off type burner with 5/32" hex (Allen) wrench. of gas converted to on card. Also, indicate conversion by 14. Insert Appropriate Propane Gas pilot injector adding “Conv.” behind type of gas. orifice into pilot burner using the 5/32" hex wrench. 15. Re-install pilot hood to pilot assembly. Push downward to snap in place. Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 2 41317-1-0220...
  • Page 3 — POUR CONVERSION AU GAZ PROPANE AVERTISSEMENT Ce nécessaire de conversion doit être installé par un distributeur Empire Comfort Systems Inc. (ou une agence qualifiée )* conformément aux instructions du fabricant et à tous les codes et exigences de l’autorité ayant juridiction. Le défaut de respecter les directives pourrait résulter en de grave blessure ou dégâts matériels.
  • Page 4 MARQUÉ 1,55 mm = taux d’entrée (Btu/h). Sur les installations sans 12. Tirer le capot de la veilleuse vers le haut pour le retirer compteur de gaz, vérifier la pression du collecteur. et avoir accès à l’orifice de l’injecteur de la veilleuse. Si le foyer n’est pas installé ou que la carte de garantie n’a 13. Enlever l’orifice de l’injecteur de la veilleuse au Gaz pas été retournée à Empire Comfort Systems, Inc., cocher Naturel du brûleur de la veilleuse à l’aide d’une clé le type de gaz converti sur la carte. Indiquer également la hexagonale (Allen) de 5/32 po. conversion en ajoutant « Conv. » derrière le type de gaz. 14. Insérer l’orifice approprié d’injecteur de veilleuse au Gaz Propane dans le brûleur de la veilleuse à l’aide d’une clé hexagonale de 5/32 po. Empire Comfort Systems Inc. Belleville, IL Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez communiquer avec votre revendeur. www.empirecomfort.com Page 2 41317-1-0220...