Important Remarks; User Instructions; Important Safety Instructions; Installation Instructions - Cardin Elettronica EL Serie Manuel D'instructions

Masquer les pouces Voir aussi pour EL Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

IMPORTANT REMARKS

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS CARE-
FULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL
THE PARAGRAPHS MARKED WITH THE SYMBOL
TIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.
These instructions are aimed at professionally qualified "INSTALL-
ERS OF ELECTRICAL EQUIPMENT" and must respect the local
standards and regulations in force. All materials used must be
approved and must suit the environment in which the installation
is situated.
• All maintenance operations must be carried out by professionally
qualified technicians. Before carrying out any cleaning or main-
tenance operations make sure the power is disconnected at the
mains.
• This appliance must be used exclusively for the purpose for which
it has been made. "i.e. for traffic control". The appliance may be
used to control passageways with a maximum width of 3m.
• The unit may be fitted both to the right and to the left of the pas-
sageway.
• This product and all its relative components has been designed
and manufactured by Cardin Elettronica who have verified that
the product conforms in every aspect to the safety standards in
force.
Any non authorised modifications are to be considered improper
and therefore dangerous. The manufacturer accepts no liability for
situations arising from the use of an electrical installation which
does not conform to the local standards and regulations in force
and in particular when the earthing circuit is not efficient.

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Ensure that the boom operating installation is far enough away from
the main road to eliminate possible traffic disruptions.
2) In its vertical movement the boom must not come into contact with
overhead cables and other such obstacles.
3) The boom operator is designed for use on passageways through
which vehicles are passing. Pedestrians should use a separate
entrance.
4) The boom must be in full view when it is operating therefore controls
must be situated in a position where the operator can see the boom
at all times.
5) At least two warning signs (similar to the example on the right) should
be placed, where they can be easily seen by the public, in the area
of the system of automatic operation. One inside the property and
one on the public side of the installation.
These signs must be indelible and not hidden by any objects (such
as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children
and/or pets must not be allowed to play within the
area of an automatic installation. If possible include
this in the warning signs.
7) A correct earth connection is fundamental in order
to guarantee the electrical safety of the machine
8) If you have any questions about the safety of the
barrieroperatingsystem,donotinstalltheoperator.
Contact your dealer for assistance.
TECHNICAL DESCRIPTION
710/EL3024
Electromechanical barrier with a 24Vdc motor,
incorporated electronics, buffer battery, automatic
and semiautomatic functions, torque limiter and
S449 radio frequency decoder.
716/EL3024A Ø 60 mm - 3000 mm long bar complete with bar
holder arm with which to connect it to the barrier
IMPORTANT REMARKS
. NOT READING THESE IMPORTANT INSTRUC-
- 24Vdc motor with a steel never ending screw.
- Carter in shock-proof plastic.
- Manual release components in reinforced plastic.
- Geared motor with steel gears enclosed in a die cast two-piece
aluminium shell.
- Motor support base in zinc-plated steel
- Boom holder in die cast aluminium.
- Lubrication using permanently fluid grease.
- Barrier cabinet in spray painted die cast aluminium.
- Incorporated warning light.

USER INSTRUCTIONS

During the opening/closing manoeuvre check for correct operation
and activate the emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeu-
vred (see manual release pag.12).
Attention! The boom is not balanced and must be held
during manual release
In case of failure or operational anomalies switch off the power at
the mains do not attempt to repair the appliance yourself.
Periodically check the correct operation of all safety devices
(photoelectric cells etc.)
Eventual repair work must be carried out by specialised personnel
using original spare parts.
The appliance is suitable for continuous operation (see technical
data on page 20).

INSTALLATION INSTRUCTIONS

• The minimum controls which may be installed are OPEN-
STOP-CLOSE, these controls must be installed in a location
not accessible to children.
• The ground must be stable enough to firmly hold the plinth and
the anchor plates.
• Where possible protect the barrier cabinet from accidental
knocks by passing vehicles.
• Work out the run of the cables according to the command and
control devices fitted and make sure the system conforms to the
local standard and regulations in force (see installation example
fig.1 pag. 2).
FITTING THE UNIT
- prepare a cement base with the base plate and anchors "A"
embedded. The cable passage tube "B" and the four threaded
bolts "D" M8 must protrude (30mm) from the base plate.
WARNING
- the base plate must be perfectly in square, its surface must be
AUTOMATIC OPENING
clean and the four threaded bolts must emerge perpendicu-
KEEP CLEAR
larly.
Note: the cement base should preferably protrude 50 mm out of
the ground in order to avoid water build up which could damage
the appliance.
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
• To install the barrier proceeds as follows:
NEAR THE INSTALLATION
- remove the 4 self locking nuts "D" from the four threaded bolts
(used to fasten down the anchors) and insert the base of the
barrier "C". Fasten down the barrier using the 4 self locking nuts
and washers "D" supplied with the appliance.
- it is also possible to fasten the barrier to an already existing
cement base as long as the thickness of the base is great enough
to guarantee a strong hold for the rawlplugs.
We advise you to use the following type of rawlplug: "Steel
anchor bolts M8/diam. 14 for heavy duty use".
11