HOW IT WORKS

The SI200 internal alarm siren disorientates and causes the intruder stress.
Used with the base unit siren, the internal alarm siren allows you to increase the power of the
siren sound inside the house, or to make it ring for longer.
You can delay triggering the internal alarm siren in order to prolong the overall length of ring
for your system.
If there is a fire, and you have a smoke detector, the internal alarm siren will sound with a
specific ring for 5 minutes.
The internal alarm siren is only compatible with DIAGRAL TwinPass
units.
FEATURES
TwinPass® radio transmission
Personalised radio code
2 different alarm rings: internal deterrent and fire
Sound level 110 dBA
Length of ring:
}
- 10 seconds advance alarm
deterrent ring
- 90 seconds intruder
- 5 minutes fire siren
Siren is triggered:
- depending on the entry delay set on the base unit, if there is an advance alarm
- immediate or delayed (10 or 60 seconds) if there is an intruder
- immediate if there is an emergency call, fire or tamper protection alert
Protected round the clock against any attempt to pull it from the wall or cut the 2 aerials.
Functions independently for 2 years with the 4 alkaline batteries 9 V supplied (under nor-
mal domestic conditions of use)
ADVICE FOR SAFE INSTALLATION
Install the siren:
high up, more than 5 metres away from the base unit, the telephone transmitter, another
siren or a receiver.
as far as possible from any potential sources of static (electric calculator, telephone junction
box, computers, etc.)
to be as much of a deterrent as possible.
YOU WILL NEED
A Phillips screwdriver
®
. and a flat bladed screwdriver
A drill with a 6mm concrete bit,
The 4 alkaline batteries (supplied).
The coding tool and the coding template supplied: 3 plugs, 3 dome headed screws, 3 x 3
mm metal washers, and 1 plastic washer.
1 tamper sensor, 2 aerial tubes (supplied) 2 aerial end pieces (supplied).
GB

INSTALLATION INSTRUCTIONS

If you are adding this product to an existing alarm system, you will need:
either the coding tool and template used to code the components of the alarm system, in
which case go directly to the paragraph "Coding the personalised radio code" in these ins-
tructions,
or the coding tool and template supplied in the accessory kit included, in which case carry
out the following coding procedure:
use the chart you used to put the radio code on the base unit (see Alarm siren installa-
1
tion guide or system installation guide),
®
base
take the coding template, turn it over and you will see the numbers 1 to 10,
2
hold the template and put the point of the coding tool into the first hole corresponding
3
to the figure with the first cross on the grid,
twist the coding tool clockwise to pierce the template. Stop when the point of the
4
coding tool has completely penetrated to the other side. This means the hole has been pro-
perly made,
repeat the last two steps for each figure corresponding to a cross on the grid. Now,
5
you will have reproduced your code on the coding template,
now go to the paragraph "Coding the personalised radio code".
6
FIG. A
Front view of the alarm siren
Front.
Siren sound holes.
FIG. B
Opening the alarm siren
Locking notch.
Insert a flat bladed screwdriver at
cover.
FIG. C
Guarantee sticker
Detach the pre-cut section of the guarantee sticker, which is on the back of the siren and
stick it on to the guarantee extension request supplied with the base unit documents
If you are adding to an existing system, use the guarantee extension request supplied with
the product.
FIG. D
Coding the personalised radio code
Place the coding template positioning pins in the corresponding holes.
1
Hold the template and put the point of the coding tool in the first open hole of the templa-
2
te.
Press on the coding tool while turning it clockwise to break the corresponding coding
3
connection. Stop when the handle of the coding tool reaches the coding template.
Repeat the procedure for each hole in the template.
Remove the coding template, making sure the cut pieces fall outside the detector. Check
4
that the coding connections corresponding to your personalised radio code have been cor-
rectly cut (Diagram
18
Aerials.
Opening for locking screw.
and press the locking tab while lifting up the front
: connection intact; Diagram
: connection cut).
GB
19

Publicité

Table des Matières
loading

Table des Matières