Application; Mode Of Operation; Safety Instructions - Kemper variohood 232 03 02 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Application

The modular extraction hood KEMPER variohood is used to exhaust contaminated air which is generated during welding and cutting in the
metal industry. Thanks to the unique stream principle it is possible to achieve a high extraction efficiency at a very low air consumption.
By connecting the exhaustion hood to extraction – and filter units, the exhausted air can be transported. In order to guarantee a high exhaustion
efficiency, please maintain the following airflow.
Part No.
232 03 02
232 04 02
232 05 02
232 06 02
232 03 03
232 04 03
232 05 03
232 06 03
232 04 04
232 05 04
232 06 04
232 07 04
The KEMPER variohood is intended to be connected to a KEMPER system 6000, 8000 or 9000. Your contact person will be pleased to advise
you.

2. Mode of operation

Thanks to the unique flow principle, it is possible to achieve a high extraction efficiency at a very low air volume. The produced dust is drawn
through small, elongated openings on the inner edges of the extraction hood. This minimizes the loss of pressure.
The extraction hood is fully fitted out with strips to optimally capture the air and the dust incurred during welding and cutting cannot escape.
Furthermore the occurrence of sparks is reduced, thus protecting not only the staff but the entire equipment.
The length of the strips can be individually altered to suit your requirements.

3. Safety instructions

Make sure that everyone who works on the extraction and filter unit is qualified, proceeds as required by the rules and respects the health and
safety standards.
Profound knowledge is required for the installation and maintenance of the units.
Before starting to work, turn the extraction or filter unit off. In order to prevent accidents, please also proceed as explained above for even small
works on the unit.
14
Dimensions
Required
[mm]
airflow
[m³/h]
1.350 x 900 x 300
1.700
1.800 x 900 x 300
2.300
2.250 x 900 x 300
2.900
2.700 x 900 x 300
3.500
1.350 x 1.350 x 300
2.300
1.800 x 1.350 x 300
3.000
2.250 x 1.350 x 300
3.800
2.700 x 1.350 x 300
4.600
1.800 x 1.800 x 300
3.700
2.250 x 1.800 x 300
4.700
2.700 x 1.800 x 300
5.600
3.150 x 1.800 x 300
6.500
Pressure loss
Number of
[Pa]
suction spigots
Ø 250 mm
[pcs]
200
1
200
1
200
2
200
2
200
1
200
2
200
2
200
2
200
2
200
2
200
2
200
3

Publicité