Selve SE Plus-RC Mode D'emploi page 61

Masquer les pouces Voir aussi pour SE Plus-RC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

iveo initial operation/Setting by radio
6.1.2. Manual setup-mode, deletion and manual setting of the end positions
in operation bottom position, top stop/release
When the movement is interrupted once, the system is in manual setup-mode. The
drive will only find the upper end limit automatically.
Important: A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit
stop without interruption, until the motor is automatically switched off.
Caution!
Only connect the radio motor that you wish to program to the mains. It is not possible
to program more than one motor at the same time.
Setting with
transmitter
6 s
or
3 s
or
1 s
Drive
Connect to power.
Press the UP and DOWN buttons at the transmitter at the
same time. The transmitter is temporarily programmed into
the motor.
Press the STOP button of the transmitter for 6 seconds.
Move the motor to the lower end position with the UP or
DOWN button.
Press the STOP button of the transmitter for 3 seconds.
The correct rotation direction assignment will be carried out
at the end of the end position setting.
Move the drive with the UP or DOWN button against the
upper limit stop. The motor stops automatically and
relieves shortly.
Press the PROG button at the transmitter.
The transmitter is now permanently programmed.