Selve SE Plus-RC Mode D'emploi page 55

Masquer les pouces Voir aussi pour SE Plus-RC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

commeo initial operation/Setting by radio
Note for settings under point 5.2.: The motor must be selected for this setting with
a transmitter in SELECT mode (Status LED flashes slowly in orange). After completing
the setting, the motor is still selected (see point 5.).
5.2.3. Manual setup-mode, deletion and manual setting of the end positions
in operation bottom position, top position
When the movement is interrupted once, the system is in manual setup-mode.
In manual setup-mode, the lower end position must be set and stored first. Afterwards,
the upper end position can be set and stored. Drive against the top stop until the motor
is automatically switched off.
Operation
6 s
or
3 s
or
3 s
Drive
Press the STOP button of the transmitter for 6 seconds.
The motor will switch to manual setting mode. Both limit
positions already set will be deleted.
Move the motor to the lower end position with the UP or
DOWN button.
Press the STOP button of the transmitter for 3 seconds.
The correct rotation direction assignment will be carried out
at the end of the end position setting.
Move the motor to the designated upper end position.
Press the STOP button of the transmitter for 3 seconds.
The end positions are now set and the rotation direction
assignment is correct. Perform a test run.
Note: The transmitter may not yet have been programmed.
See point 5.2.4. to program a transmitter.