Fireplace Installation
Figure 6
Glass
Partially
Openings
Reflective Glass
• Connect the L wire from the
unit to the live wire
main power through the
wall switch, ensuring all live
connections are connected
with a wire nut.
• Connect the N wire from the
unit to the neutral wire from
the power supply with a wire
nut.
• Connect the G wire from the
unit to the ground wire from
the power supply with a wire
nut or attach the grounding
wire to the cover with the
provided grounding screw, by
placing the wire in-between
screw and lock washer and
tighten (Figure 3).
Retaining
Bracket
Media Tray
from the
• Ensure that all wires are
secure and do not protrude
past the flame panel, so as
not to be visible after final
assembly.
• Continue to the final assembly
instructions.
240V Installations
Use three conductor, non-metallic
sheath cable with ground wire
(4 wires total) for the incoming
power supply on fireplace inserts.
CAUTION: Use the
appropriate wire to meet local
and national electrical codes
for rated power consumption.
• Connect the L1 wire from the
unit to the L1 wire from the
power supply with a wire nut.